Mark S. Brown edited Standard table.tex  about 10 years ago

Commit id: fadee0c1b2818c1aa0bad0993ba297f9799036d0

deletions | additions      

       

\caption{\label{tab:standardctr} Standard coincidence apparatus measurements for two identical polished Proteus LYSO:Ce scintillator crystals wrapped in PTFE tape. All crystals have a cross section of $2\times2$ mm$^2$. $\chi^2_\text{Reduced}$ is the reduced chi-squared fit to the delay peak.}  \begin{tabular}{cccccccc}  \hline  Wrapped By & length (mm) & Left Energy Resolution (\%) & Right Energy Resolution (\%) & Detected $\gamma\gamma$ Events &Valid $\gamma\gamma$ Events &  Delay Peak Centroid (ps) & CTR (ps)\\ \hline  Wrap 1 & 5 & 7.05$\pm$0.07 & 9.44$\pm$0.09 & 856$\pm$29 & 11177$\pm$106 & -68.8$\pm$2.4 & 154.9$\pm$4.9 \\  Wrap 2 & 5 & 6.33$\pm$0.08 & 7.36$\pm$0.09 & 361$\pm$19 & 6344$\pm$80 & -68.8$\pm$3.4 & 140.8$\pm$6.7 \\