\section*{Appendix - Full Results}  \subsection{Standard}  \begin{table}   \caption{\label{tab:standardctr} Standard coincidence timing measurements on Proteus LYSO:Ce scintillator crystals}  \begin{tabular}{lrllllr}  configuration & length (mm) & Energy Resolution (\%) & Detected $\gamma\gamma$ Events & Delay Peak Centroid (ps) & CTR (ps) & $\chi^2_\text{Reduced}$ \\  \hline 