Ning Zhu edited subsection_Direct_Fit_Method_We__.tex  over 8 years ago

Commit id: 7ff88a80a218da18389a66840cc3daea26055e77

deletions | additions      

       

\subsection{Direct Fit Method}  We plott plot  the photodiode voltage versus angle of the polarizer with and without a magnetic field applied as shown in figure \ref{fig:directmethoddata}. It can be seen from the graph that the curve shifts a little bit, which is a direct result of the magnetic field. By applying curve fit to our data points, we find the phase shift between two curves is 4 degrees($d\theta$). The current provided to induce a magnetic field is -3A, which can be translated to dB using equation \ref{magneticfield}. With these numbers, we are able to calculate Verdet constant using equation : \begin{equation}  c_v=\frac{1}{L}\frac{d\theta}{dB}  \end{equation}