this is for holding javascript data
Madeline Horn edited subsubsection_Johnson_noise_in_10K__.tex
over 8 years ago
Commit id: a4823355c304dba7ead72bd5517c6260a11c677a
deletions | additions
diff --git a/subsubsection_Johnson_noise_in_10K__.tex b/subsubsection_Johnson_noise_in_10K__.tex
index 33176c9..f601365 100644
--- a/subsubsection_Johnson_noise_in_10K__.tex
+++ b/subsubsection_Johnson_noise_in_10K__.tex
...
\subsubsection{Johnson noise
in for the $10K$ Ohm Resistor}
Refer to electronics setup photo Fig.~\ref{fig:JohnsonSetUp} for the set up of our apparatus. Our settings for the Noise Fundamentals devices were as follows: for the $10\textrm{k}\Omega$ resistor, we used a Gain 1 (G1) of $\times600$ for all values that comes directly from the Noise Fundamental device, a Gain 2 (G2) of $\times1000$ for all values, we used a measured value for room temperature of $295$ degrees Kelvin, and we varied the high and low pass filters' frequency for each data set in order to vary the bandwidth. In Table \ref{table:Johnson1}, you can see how we varied the low pass filter ($f2$) and the high pass filter ($f1$) in order to change the bandwidth. The values are taken from the multi-meter after going through the filters, gain, and multiplier. All of the values are in mV; we took $36$ sets of data points. You can see all these values in Table \ref{table:Johnson1}.