\subsubsection{Instrumental Noise: $1$ Ohm Resistor}
Our settings for the Noise Fundamentals devices were as follows: $1 \Omega$ resistor, we used a Gain 1 (G1) of $\times600$ for all values that comes directly from the Noise Fundamental device, a Gain 2 (G2) of $\times1000$ for all values, we used a room temperature of $296$ degrees Kelvin, and we varied the high and low pass filters' frequency for each data set in order to vary the bandwidth. In Table.~\ref{table:Johnson1}, you can see how we varied the low pass filter
(f2) ($f2$) and the high pass filter
(f1) ($f1$) in order to change the bandwidth. The values are taken from the multi-meter after going through the filters, gain, and multiplier. All of the values are in mV; we took $36$ sets of data points. You can see all these values in Table 3.