Madeline Horn edited subsubsection_Johnson_noise_for_the__.tex  over 8 years ago

Commit id: 253dcc85613c2170388d3b900f5b3a1bf9059ee5

deletions | additions      

       

\subsubsection{Johnson noise for the $10K$ Ohm $10k \Omega$  Resistor} Refer to electronics setup photo Fig.~\ref{fig:JohnsonSetUp} for the set up of our apparatus. Our settings for the Noise Fundamentals devices were as follows: for the $10\textrm{k}\Omega$ resistor, we used a Gain 1 (G1) of $\times600$ for all values that comes directly from the Noise Fundamental device, a Gain 2 (G2) of $\times1000$ for all values, we used a measured value for room temperature of $295$ degrees Kelvin, and we varied the high and low pass filters' frequency for each data set in order to vary the bandwidth. In Table \ref{table:Johnson1}, you can see how we varied the low pass filter ($f2$) and the high pass filter ($f1$) in order to change the bandwidth. The values are taken from the multi-meter after going through the filters, gain, and multiplier. All of the values are in mV; we took $36$ sets of data points. You can see all these values in Table \ref{table:Johnson1}. \ref{table:Johnson1}