Nathanael A. Fortune added Once_the_measured_spacings_Delta__.tex  over 8 years ago

Commit id: e25b065d6c5f35330b851e00c83713cd03fb1f95

deletions | additions      

         

Once the measured spacings, ($\Delta E_{n}$), between the maxima and minima of the Franck-Hertz curve were plotted against the minimum order (n) of the peaks and dips, and analyzed using a linear fit in order to see if they were consistent with the expected equation for the difference in energy gained.\\  Due to poor resolution in some of the acquired data, it was very difficult to determine the minimum order (n) of the peaks and dips. The presumed true value of n was found via trial and error, thus we expect there to be some uncertainty on it.