Anisha Keshavan edited A_few_scans_failed_initial__.tex  about 8 years ago

Commit id: c310bd9a26268b44164157521dda24c93df55c2a

deletions | additions      

       

A few scans failed initial QC due to small amounts of dura classified as brain at the top of the head that required editing and were mistakenly excluded. These scans are now included and do not change the results (in particular, $CV_a$, as this is the most important for power calculations). We have included the results from the revised dataset in the manuscript. For the new QC procedure, eTIV was checked as suggested by the reviewer; this QC check is advantageous in being the first step of the in recon-all and is sensitive to misregistration to the talairach template that could lead to inaccurate segmentations overall. Finally only 3 scans were rejected due to failing QC at the registration step step,  which were all from the same subject from sites 4 and 6 and second subject at site 11. Three other scans were not included due to acquisition/ data transfer issues: One scan was not acquired due to time constraints, one scan was left out because part of the head was not acquired (possibly the files were corrupted), and one scan was erroneously deleted at the site. A column has been added in the acquisition tables to reflect how many actual scans were acquired at each site.