Rein D. Otsason added EM Calc Sensor Array.tex  about 10 years ago

Commit id: 9a74731db3193569e59bd733e2a8573f0b097c2b

deletions | additions      

         

\subsubsection{Sensor Array Material Calculations}  The initial estimate of the weight of the sensor array was $800~\mathrm{g}$.  The selected material for the lines under tension lifting the sensor array was 10-pound test fishing line,  which has a yield strength of $45~\mathrm{N}$.  With four lifting points at the corners of the sensor array,   it is unlikely that any line holds more than 50\% of the weight,  but assuming for the purposes of the the calculation that a single point holds 100\%,  the maximum load is $0.8~\mathrm{kg} \times 9.82~\mathrm{m \cdot s^{-2}} = 7.9~\mathrm{N}$.  This gives a factor of safety of $5.65$ under an extremely unlikely scenario,   so the material selection is valid.