this is for holding javascript data
Liisa Hirvonen edited Results2.tex
over 8 years ago
Commit id: cb7cb9504efe2c7761deec76b6281768a09f79f4
deletions | additions
diff --git a/Results2.tex b/Results2.tex
index cf254ac..a90ecc1 100644
--- a/Results2.tex
+++ b/Results2.tex
...
ThunderSTORM's option for Multi-emitter Fitting Analysis (MFA) produces excellent results with recognising and separating overlapping EBCCD photon events, as shown in Fig~\ref{fig_mfa}. For the USAF data containing an average of 150 photons/frame the photon count increases 2\% with MFA enabled.
Centroiding was then applied to higher photon density fluorescence microscopy data of
F-actin in a fixed cell labelled with
xxxx. Alexa-488. The frames contain an average of 460 photons/frame (Fig~\ref{fig_cell}). With 7-pixel PSF fitting radius and MFA enabled, the photon count increases 13.0\% compared to using 2-pixel fitting radius, and 5.2\% compared to 7-pixel fitting radius without MFA. Fitting of multiple PSFs is time-consuming and the processing time increases significantly with MFA enabled, as expected (see Table~\ref{table:results}). However, for biological imaging the image acquisition time is a critical parameter, and the separation of overlapping events can potentially lead to significant reduction in image acquisition times.