Pol Grasland-Mongrain edited Introduction.tex  over 7 years ago

Commit id: e418ea02653099d2d62c10b6c419ed6596de30fa

deletions | additions      

       

While the induction of surface acoustic waves by laser in soft tissues was recently demonstrated by Li et al. \cite{Li_2012}, \cite{Li_2014}, a similar phenomenon with shear waves in bulk medium has never been described. This is of great interest for the shear wave elastography technique. As its name indicates, shear wave elastography comprises the techniques used to map the elastic properties of soft media using shear wave propagation \cite{Plewes_1995}, \cite{muthupillai1995magnetic}, \cite{Catheline_1999}. These techniques typically use low frequency (50-500 Hz) shear waves so that their propagation can be observed over a few centimeters. The shear waves are currently generated using either an external shaker or a focused acoustic wave. However, alternative shear wave generation methods have drawn important attention recently. For example, it has been demonstrated that one can use natural motion of the medium \cite{Hirsch_2012}, \cite{Zorgani_2015}, the Lorentz force \cite{Basford_2005}, \cite{Grasland_Mongrain_2014}, \cite{Grasland_Mongrain_2016} or electrolysed-induced bubbles \cite{Montalescot_2016}. Compared to these generation sources, a laser presents the advantage of being fully remote, without need of coupling gel; and of being miniaturizable at low cost using an optical fiber.  In our experiment, illustrated in Figure \ref{Figure1}, we used a Q-switch Nd:YAG laser (EverGreen 200, Quantel, Les Ulis, France) to produce a 10-ns pulse of 10 to 200 mJ energy at a central wavelength of 532 nm in a 5-mm diameter circular beam. The laser beam was absorbed in a 4x8x8 cm$^3$ black mat phantom composed of water, 5\% polyvinyl alcohol, and 1 \% black graphite powder. Two freeze/thaw cycles were applied to stiffen the material to a shear modulus of 25$\pm$5 kPa \cite{17375819}. To observe the resulting shear waves, the medium was scanned simultaneously with a 5-MHz ultrasonic probe, consisting of 128 elements, connected to a multi-channeled ultrasound scanner (Verasonics V-1, Redmond, WA, USA). The probe was acquiring 4000 ultrasound images per second during 30 ms. Due to the presence of graphite particles, the medium presented a speckle pattern on the ultrasound image.\textcolor{red}{The computation of displacements along the Z axis (the ultrasound axis) was computed by tracking the speckle spots with the Lucas-Kanade method \cite{lucas1981iterative}. This method solves basic optical flow equations by least squares criterion ina  64x5 pixels windows around each pixel.} Displacements over time were then filtered from 200 to 800 Hz using a 5th-order Butterworth filter and averaged over four experiments.