Pol Grasland-Mongrain edited Introduction.tex  over 8 years ago

Commit id: ac9d6d42b1275baf63561b03540881adf69a3245

deletions | additions      

       

u_z = \frac{(3\lambda + 2\mu)}{(\lambda + 2\mu)} \frac{\alpha E \zeta}{\rho C S \zeta}  \label{eq:deplThermo}  \end{equation}  As in a biological soft tissues, $\mu \ll \lambda$, the displacement $u_z$ can be approximated as $\frac{3 \alpha E}{\rho C S}$. Taking as an order of magnitude $\alpha$ = 70.10$^{-6}$ K$^{-1}$ (water linear thermal dilatation coefficient), $E$ = 200 mJ, $\rho$ = 1000 kg.m$^{-3}$ (water density), $C$ = 4180 kg.m$^{-3}$ (water calorific capacity) and $S$ = 20 mm$^2$, we obtain a displacement $u_z$= 0.5 $\mu$m. This value is slightly smaller than the typical ultrasound elastography resolution (5--10 $\mu$m \cite{22545033}. \cite{22545033}).  In a 3D model, displacements along X and Y axis would also occurs, as the local expansion acts as dipolar forces parallel to the surface. In the ablative regime, the local increase of temperature is so high that the surface of the medium is vaporized. This phenomenon creates a stress $\sigma_{zz}$ in the medium, as the sum of the P-wave modulus and a term given by the second law of motion \cite{scruby1990laser}:  \begin{equation} 

\end{equation}  As in a biological soft tissues, $\mu \ll \lambda$, the displacement $u_z$ can be approximated as $\frac{\zeta}{\rho \lambda}\frac{E^2/S^2 \tau^2}{(L+C(T_V-T_0))^2}$. Estimating $\zeta$ equal to 50 $\mu$m (average depth of absorption), $\lambda$ = 2 GPa (first Lamé's coefficient of water), $L$ = 2.2 MJ.kg$^{-1}$ (vaporization latent heat of water), $C$ = 4180 J.kg$^{-1}$.K$^{-1}$ (water heat capacity), $T_V-T_0$ = 373-293 = 80 K (water vaporization temperature minus laboratory temperature), $\rho$ = 1000 kg.m$^{-3}$ (water density), $E$ = 200 mJ, $S$ = 20 mm$^2$ and $\tau$ = 10 ns, we obtain a displacement $u_z$ approximately equal to 3.9 $\mu$m. This value is eight times higher than the one obtained with thermoelastic expansion.  In both cases, absorption of the laser by the phantom leads to a local displacement which can propagate as elastic waves in the medium. In both cases, shear wave can occur because of the limited size of the source. To observe the shear waves, the medium was scanned with a 5 MHz ultrasonic probe made of 128 elements connected to a Verasonics scanner (Verasonics V-1, Redmond, WA, USA). The probe was used in ultrafast mode \cite{bercoff2004supersonic}, acquiring 1500 ultrasound images per second. Due to the presence of graphite particles, the medium presented a speckle pattern on the ultrasound image. Tracking the speckle spots with an optical flow technique (Lucas-Kanade method) allowed to compute one component of the displacement in the medium (Z-displacement or Y-displacement, depending on the position of the probe on the medium). The laser beam was triggered 10 ms after the first ultrasound acquisition, $t$ = 0 ms being defined as the laser emission.