\label{tab:pf-limits} Primary failure mode limits
Facility Operation Mode \(I_{\hbox{nom}}\) \(I_{\hbox{inj}}\) \(I_{\hbox{tol}}\) \(I_{\hbox{min}}\)
(mA) (mA) (mA)
ALBA decay 120.0 72.0 72.0 photon shutter (PhS)
ALBA top-up 100.0 98.5 95.0 PhS
BESSY II MB 299.0 299.0 272.0 PhS or 200\(\,\)mA
BESSY II SB 14.0 13.5 12.0 PhS or 8\(\,\)mA
Elettra 2.0\(\,\)GeV 310.0 309.0 307.5 0\(\,\)mA
Elettra 2.4\(\,\)GeV 160.0 159.0 158.0 0\(\,\)mA
LNLS-UVX decay 250.0 130.0 60.0 PhS or 60\(\,\)mA
PETRA III top-up 101.0 100.0 75.0 75\(\,\)mA
SPring-8 top-up 99.5 99.5 99.4 0\(\,\)mA
SLS top-up 402.0 400.0 399.0 20\(\,\)mA