Andreas Luedeke edited sectionPROPOSED_SECO.tex  over 8 years ago

Commit id: bf7a4f6734ecbe8f1db26c842c89033760a9dbea

deletions | additions      

       

\begin{tabular}{lrrl}  \textbf{Facility}&\textbf{typical size}&\textbf{blowup}&\textbf{Remark}\\\hline  & (µm x µm) & & \\  ALBA & 70 x 30 & 20\% +20\%  & recorded \\ BESSY II & 250 x 14 & 30\% +30\%  & recorded \\ Elettra & 260 x 10 & 10\% +10\%  & no on-line measurement yet \\ LNLS-UVX & 1000 x 120& 10\% +10\%  & recorded \\ PETRA III & 140 x 7 & - & no on-line measurement\\  SPring-8 & 100 x 12 & - & not an independent failure mode\\  SLS & 50 x 10 & 50\% +50\%  & recorded and evaluated \\ \end{tabular}  \end{ruledtabular}  \end{table} 

An independent recording would enable to calculate beam availability with and without accounting for the ``short-user-time'.  This would improve the comparison between facilities that handle ``short-user-time'' differently.