Ardo Illaste edited res_fitting.md  about 10 years ago

Commit id: da079b1e7548c2814ad3f7c1d1f0048679ca874f

deletions | additions      

       

F_i(t) = b(\mathbf{q}_i, t) + \sum_{k=0}^{m} f(\mathbf{p}_{i,k},t) + W  \]  , where \(b\) is a n-th order polynomial with \(\mathbf{q}_i\) being the coefficients for the *i*-th pixel.   Because it is not know which part of the signal is the event and which is the baseline the first fit also has to estimate the baseline properties.  Signal in the candidate region is fitted with an extended fit function (Figure \ref{fig:fig2}) that also depends on relaxation baseline \(B\) and baseline offset \(C\). The \(C\) parameter allows for the possibility of an elevated background before the release event.